No. of Contacts 3-8Locking Mechanism Snap-InTermination MultipleWire Gauge Max 0.25mm²Cable Diameter Range 3-5mmNominal Voltage Max. 125VNominal Current Max. 1-3AIngress Protection IP67Moulded Cable Option Yes
-
No. of Contacts 8Locking Mechanism BayonetTermination MultipleWire Gauge Max 0.25mm²Cable Diameter Range 2.5-8mmNominal Voltage Max. 175VNominal Current Max. 2AIngress Protection IP67Moulded Cable Option No
-
No. of Contacts 3-8Locking Mechanism ScrewTermination MultipleWire Gauge Max 0.50mm²Cable Diameter Range 3-5mmNominal Voltage Max. 30-60VNominal Current Max. 1.5-4AIngress Protection MultipleMoulded Cable Option Yes
-
No. of Contacts 2-78Locking Mechanism Hood with ScrewsTermination MultipleWire Gauge Max 8.40mm²Nominal Voltage Max. Available on RequestNominal Current Max. 2-40AIngress Protection MultipleMoulded Cable Option No
-
No. of Contacts 4-17Locking Mechanism ScrewTermination Solder CupWire Gauge Max 1.50mm²Cable Diameter Range 8-14mmNominal Voltage Max. 50VNominal Current Max. 2-10AIngress Protection IP67Moulded Cable Option No
-
No. of Contacts 2-8Locking Mechanism ScrewTermination MultipleWire Gauge Max 0.25mm²Cable Diameter Range 3.5-5mmNominal Voltage Max. 125VNominal Current Max. 1-4AIngress Protection IP67Moulded Cable Option Yes
-
No. of Contacts 6-19Locking Mechanism ScrewTermination Solder CupWire Gauge Max 2.50mm²Cable Diameter Range 6-10mmNominal Voltage Max. 60-250VNominal Current Max. 7.5-16AIngress Protection IP67Moulded Cable Option No
-
No. of Contacts 4 & 8Locking Mechanism ScrewTermination MultipleWire Gauge Max 0.75mm²Cable Diameter Range 5-8mmNominal Voltage Max. 250VNominal Current Max. 4AIngress Protection IP67Moulded Cable Option Yes
-
No. of Contacts 2-47Locking Mechanism Hood with ScrewsTermination MultipleWire Gauge Max 8 AWGNominal Voltage Max. Available on RequestNominal Current Max. 2.5-40AIngress Protection IP67Moulded Cable Option No
-
No. of Contacts 3-19Locking Mechanism ScrewTermination MultipleWire Gauge Max 4mm²Cable Diameter Range 3-17mmNominal Voltage Max. 24-630VNominal Current Max. 3-28AIngress Protection MultipleMoulded Cable Option No
Degrees of Protection - First Digit
The degree to which people are protected against contact with moving parts and the level of protection to prevent solid foreign bodies entering an enclosure is shown by an IP code's first digit.
Degrees of Protection - Second Digit
The second digit of the IP code reveals the degree of protection against dripping, submersion and other forms of moisture regarding the equipment inside the enclosure.